| Model | PA-H020A | PA-H040A | PA-H060A | PA-H100A | PA-H200A |
| Maximum Output Current | 20 Amps DC | 40 Amps DC | 60 Amps DC | 100 Amps DC | 200 Amps DC |
| Duty cycle | 5% @ 20A | 5% @ 40A | 5% @ 60A | 5% @ 100A | 5% @ 200A |
| Open circuit voltage | 80VDC | 60VDC | 60VDC | 45VDC | 45VDC |
| Options | 1,2 or 4 outputs | 1 or 2 outputs | 1 output Multi output on request | 1 output Multi output on request | 1 output |
| Mains supply 50/60Hz | 110V/230VAC +/-15% | 110V/230VAC +/-15% | 110V/230VAC +/-15% | 380 / 415 / 460VAC 3 phase | 380 / 415 / 460VAC 3 phase |
| Up slope time (0.1 ms steps) | 0.1 - 99.9 ms | 0.1 - 99.9 ms | 0.1 - 99.9 ms | 0.1 - 99.9 ms | 0.1 - 99.9 ms |
| Peak weld time (0.1 ms steps) | 0.1 - 999.9 ms | 0.1 - 999.9 ms | 0.1 - 999.9 ms | 0.1 - 999.9 ms | 0.1 - 999.9 ms |
| Down slope time (0.1 ms steps) | 0.1 - 999.9 ms | 0.1 - 999.9 ms | 0.1 - 999.9 ms | 0.1 - 999.9 ms | 0.1 - 999.9 ms |
| 2nd pulse weld delay time | 1 - 999 ms | 1 - 999 ms | 1 - 999 ms | 1 - 999 ms | 1 - 999 ms |
| Cooling (overheat protected) | Fan | Fan | Fan | Fan | Fan |
| Max gas pressure | 1 Bar - Single Output | 1 Bar - Single Output | 1 Bar - Single Output | 1 Bar - Single Output | 1 Bar - Single Output |
| Gas pre/purge timing | Programmable | Programmable | Programmable | Programmable | Programmable |
| WEIGHT & DIMENSIONS | |||||
| Dimensions (D x W x H) | 490 x 270 x 300mm | 490 x 270 x 300mm | 490 x 270 x 300mm | 445 x 560 x 220mm | 445 x 560 x 220mm |